Altiplano Híbrido

Needs attention

Murcia · Wind + solar + storage · 74 MW installed · 8 technicians · manager John Ingram

Output now

5.2 MW

Load factor

7 %

Energy today

123 MWh

Availability

97.1 %

Producing

21 / 29

Open alarms

10

Generation
Last 12 hours
Wind, solar and battery power at the point of interconnection. A charging battery shows below zero.
Conditions
Resource and grid

Wind

7.4 m/s SSW

Irradiance

324 W/m²

Temperature

24.3 °C

Cloud cover

48 %

Conditions

Partly cloudy

Substation

Yecla SE 220 kV

Voltage

219.2 kV

Frequency

49.999 Hz

Power factor

0.994

Curtailment

7 %

Day-ahead price

101.56 €/MWh

Assets

29 assets on site. Open one for its live 3D view.

Power flow

Wind turbine

WTG-01

Siemens Gamesa SG 6.6-170 · 5.0 MW

Maintenance
0%

Output

0.00 MW

Today

8.0 MWh

Wind

7.1 m/s

Wind turbine

WTG-02

Nordex N163/5.X · 4.2 MW

Producing
0%

Output

0.01 MW

Today

11.1 MWh

Wind

3.8 m/s

Wind turbine

WTG-03

Siemens Gamesa SG 6.6-170 · 4.2 MW

Producing
22%

Output

0.91 MW

Today

8.3 MWh

Wind

8.1 m/s

Wind turbine

WTG-04

Vestas V150-4.2 · 6.2 MW

Maintenance
0%

Output

0.00 MW

Today

10.0 MWh

Wind

8.6 m/s

Wind turbine

WTG-05

Vestas V150-4.2 · 5.0 MW

Maintenance
0%

Output

0.00 MW

Today

8.0 MWh

Wind

9.7 m/s

Wind turbine

WTG-06

Vestas V162-6.2 · 5.0 MW

Producing
8%

Output

0.41 MW

Today

14.8 MWh

Wind

6.4 m/s

Tracker block

PV-01

Nextracker NX Horizon · 2.4 MWp

Producing
21%

Output

0.50 MW

Today

3.3 MWh

Availability

96.3 %

Tracker block

PV-02

Soltec SF7 · 2.4 MWp

Producing
27%

Output

0.66 MW

Today

3.3 MWh

Availability

99.2 %

Tracker block

PV-03

Array Technologies DuraTrack HZ v3 · 2.4 MWp

Producing
29%

Output

0.70 MW

Today

2.8 MWh

Availability

93.3 %

Tracker block

PV-04

Array Technologies DuraTrack HZ v3 · 4.0 MWp

Producing
30%

Output

1.20 MW

Today

5.7 MWh

Availability

97.5 %

Tracker block

PV-05

Soltec SF7 · 2.4 MWp

Producing
18%

Output

0.42 MW

Today

3.3 MWh

Availability

93.0 %

Tracker block

PV-06

Soltec SF7 · 4.0 MWp

Producing
26%

Output

1.02 MW

Today

6.0 MWh

Availability

95.5 %

Tracker block

PV-07

Soltec SF7 · 2.4 MWp

Producing
26%

Output

0.63 MW

Today

3.8 MWh

Availability

99.5 %

Tracker block

PV-08

Array Technologies DuraTrack HZ v3 · 2.4 MWp

Maintenance
0%

Output

0.00 MW

Today

3.9 MWh

Availability

95.8 %

Tracker block

PV-09

Nextracker NX Horizon · 3.2 MWp

Producing
21%

Output

0.68 MW

Today

3.9 MWh

Availability

99.7 %

Tracker block

PV-10

Soltec SF7 · 4.0 MWp

Producing
20%

Output

0.78 MW

Today

6.0 MWh

Availability

94.5 %

Tracker block

PV-11

Array Technologies DuraTrack HZ v3 · 4.0 MWp

Producing
39%

Output

1.54 MW

Today

5.7 MWh

Availability

98.7 %

Tracker block

PV-12

Soltec SF7 · 3.2 MWp

Curtailed
18%

Output

0.58 MW

Today

2.2 MWh

Availability

98.7 %

Tracker block

PV-13

Soltec SF7 · 4.0 MWp

Fault
0%

Output

0.00 MW

Today

6.4 MWh

Availability

96.8 %

Tracker block

PV-14

Array Technologies DuraTrack HZ v3 · 4.0 MWp

Producing
39%

Output

1.55 MW

Today

6.0 MWh

Availability

97.3 %

Inverter skid

INV-01

Sungrow SG3125HV-MV · 4.6 MVA

Maintenance
0%

Output

0.00 MW

Today

7.4 MWh

Availability

96.9 %

Inverter skid

INV-02

Sungrow SG3125HV-MV · 3.1 MVA

Producing
25%

Output

0.76 MW

Today

4.1 MWh

Availability

96.6 %

Inverter skid

INV-03

Huawei SUN2000-215KTL · 5.0 MVA

Producing
14%

Output

0.71 MW

Today

9.1 MWh

Availability

99.4 %

Inverter skid

INV-04

Huawei SUN2000-215KTL · 3.1 MVA

Curtailed
5%

Output

0.16 MW

Today

3.1 MWh

Availability

95.4 %

Inverter skid

INV-05

SMA Sunny Central 4600 UP · 4.6 MVA

Producing
30%

Output

1.39 MW

Today

7.4 MWh

Availability

98.5 %

Inverter skid

INV-06

Huawei SUN2000-215KTL · 4.6 MVA

Producing
31%

Output

1.41 MW

Today

7.7 MWh

Availability

99.5 %

Inverter skid

INV-07

SMA Sunny Central 4600 UP · 4.6 MVA

Producing
12%

Output

0.54 MW

Today

9.2 MWh

Availability

98.7 %

Battery container

BESS-01

CATL EnerOne+ · 5.0 MW

Producing
72%

Output

3.60 MW

Today

0.0 MWh

State of charge

69 %

Battery container

BESS-02

CATL EnerOne+ · 3.9 MW

Producing
72%

Output

2.81 MW

Today

0.0 MWh

State of charge

69 %

Alarms
Site alarms
Most recent events from this site's assets.

Pitch system hydraulic pressure low

WTG-01· 11-16 13:00
Medium

Row stowed – high wind

PV-03· 11-16 12:59
Medium

Rack isolated by BMS

BESS-01· 11-16 10:05
Low

Generator winding temperature high

WTG-05· 11-16 06:36
Low

Soiling loss above threshold

PV-13· 11-16 01:22
High

Soiling loss above threshold

PV-08· 11-15 22:01
Low

Anemometer signal lost

WTG-04· 11-15 20:40
Low

Soiling loss above threshold

PV-13· 11-15 20:18
High