Alcázar Solar

Needs attention

Castilla-La Mancha · Solar PV · 35 MW installed · 4 technicians · manager Thomas Winter

Output now

7.5 MW

Load factor

21 %

Energy today

44 MWh

Availability

95.7 %

Producing

14 / 18

Open alarms

6

Generation
Last 12 hours
Wind, solar and battery power at the point of interconnection. A charging battery shows below zero.
Conditions
Resource and grid

Wind

4.2 m/s S

Irradiance

277 W/m²

Temperature

22.2 °C

Cloud cover

62 %

Conditions

Partly cloudy

Substation

Alcázar SE 220 kV

Voltage

219.3 kV

Frequency

50.005 Hz

Power factor

0.988

Curtailment

6 %

Day-ahead price

75.03 €/MWh

Assets

18 assets on site. Open one for its live 3D view.

Power flow

Tracker block

PV-01

Soltec SF7 · 2.4 MWp

Producing
34%

Output

0.82 MW

Today

3.1 MWh

Availability

94.8 %

Tracker block

PV-02

Nextracker NX Horizon · 4.0 MWp

Producing
26%

Output

1.02 MW

Today

5.5 MWh

Availability

95.0 %

Tracker block

PV-03

Nextracker NX Horizon · 2.4 MWp

Producing
34%

Output

0.81 MW

Today

3.1 MWh

Availability

93.8 %

Tracker block

PV-04

Array Technologies DuraTrack HZ v3 · 2.4 MWp

Producing
29%

Output

0.70 MW

Today

3.0 MWh

Availability

98.3 %

Tracker block

PV-05

Soltec SF7 · 3.2 MWp

Producing
24%

Output

0.77 MW

Today

4.1 MWh

Availability

97.3 %

Tracker block

PV-06

Soltec SF7 · 4.0 MWp

Standby
0%

Output

0.00 MW

Today

5.0 MWh

Availability

94.4 %

Tracker block

PV-07

Array Technologies DuraTrack HZ v3 · 2.4 MWp

Standby
0%

Output

0.00 MW

Today

3.2 MWh

Availability

97.3 %

Tracker block

PV-08

Array Technologies DuraTrack HZ v3 · 2.4 MWp

Producing
31%

Output

0.75 MW

Today

4.0 MWh

Availability

93.7 %

Tracker block

PV-09

Array Technologies DuraTrack HZ v3 · 2.4 MWp

Curtailed
11%

Output

0.27 MW

Today

1.8 MWh

Availability

94.5 %

Tracker block

PV-10

Soltec SF7 · 4.0 MWp

Producing
21%

Output

0.83 MW

Today

4.8 MWh

Availability

93.9 %

Tracker block

PV-11

Nextracker NX Horizon · 3.2 MWp

Producing
35%

Output

1.11 MW

Today

3.7 MWh

Availability

97.4 %

Tracker block

PV-12

Array Technologies DuraTrack HZ v3 · 2.4 MWp

Producing
17%

Output

0.40 MW

Today

3.1 MWh

Availability

94.0 %

Inverter skid

INV-01

Huawei SUN2000-215KTL · 3.1 MVA

Producing
21%

Output

0.64 MW

Today

3.4 MWh

Availability

95.1 %

Inverter skid

INV-02

Huawei SUN2000-215KTL · 5.0 MVA

Producing
19%

Output

0.95 MW

Today

6.0 MWh

Availability

99.1 %

Inverter skid

INV-03

Sungrow SG3125HV-MV · 4.6 MVA

Producing
25%

Output

1.13 MW

Today

5.1 MWh

Availability

98.0 %

Inverter skid

INV-04

Sungrow SG3125HV-MV · 5.0 MVA

Producing
37%

Output

1.82 MW

Today

5.5 MWh

Availability

94.9 %

Inverter skid

INV-05

Sungrow SG3125HV-MV · 5.0 MVA

Fault
0%

Output

0.00 MW

Today

8.0 MWh

Availability

94.8 %

Inverter skid

INV-06

Huawei SUN2000-215KTL · 4.6 MVA

Producing
43%

Output

1.99 MW

Today

6.9 MWh

Availability

96.1 %

Alarms
Site alarms
Most recent events from this site's assets.

Transformer oil level low

INV-05· 11-16 12:28
Medium

DC insulation resistance low

INV-05· 11-16 09:31
Medium

Row stowed – high wind

PV-10· 11-16 03:25
Low

Grid voltage out of band

INV-05· 11-16 03:13
Medium

Grid voltage out of band

INV-01· 11-15 22:25
Medium

Tracker stuck – motor current high

PV-01· 11-15 15:40
Low