Andévalo Híbrido

Needs attention

Andalusia · Wind + solar + storage · 73 MW installed · 9 technicians · manager Darragh Grealish

Output now

9.4 MW

Load factor

13 %

Energy today

146 MWh

Availability

96.6 %

Producing

21 / 26

Open alarms

6

Generation
Last 12 hours
Wind, solar and battery power at the point of interconnection. A charging battery shows below zero.
Conditions
Resource and grid

Wind

6.7 m/s SSE

Irradiance

190 W/m²

Temperature

21.8 °C

Cloud cover

94 %

Conditions

Overcast, light rain

Substation

Puebla SE 400 kV

Voltage

401.4 kV

Frequency

49.994 Hz

Power factor

0.982

Curtailment

0 %

Day-ahead price

64.91 €/MWh

Assets

26 assets on site. Open one for its live 3D view.

Power flow

Wind turbine

WTG-01

Siemens Gamesa SG 6.6-170 · 5.0 MW

Producing
31%

Output

1.53 MW

Today

12.9 MWh

Wind

8.8 m/s

Wind turbine

WTG-02

Siemens Gamesa SG 5.0-145 · 5.0 MW

Standby
0%

Output

0.00 MW

Today

10.3 MWh

Wind

9.0 m/s

Wind turbine

WTG-03

Nordex N163/5.X · 6.2 MW

Producing
7%

Output

0.44 MW

Today

23.0 MWh

Wind

6.2 m/s

Wind turbine

WTG-04

Nordex N149/4.0-4.5 · 5.0 MW

Producing
41%

Output

2.07 MW

Today

15.5 MWh

Wind

9.5 m/s

Wind turbine

WTG-05

Nordex N163/5.X · 5.0 MW

Producing
0%

Output

0.00 MW

Today

13.5 MWh

Wind

3.0 m/s

Wind turbine

WTG-06

Vestas V162-6.2 · 5.0 MW

Producing
19%

Output

0.96 MW

Today

11.9 MWh

Wind

7.9 m/s

Wind turbine

WTG-07

Vestas V162-6.2 · 5.0 MW

Fault
0%

Output

0.00 MW

Today

8.0 MWh

Wind

5.5 m/s

Wind turbine

WTG-08

Siemens Gamesa SG 5.0-145 · 6.2 MW

Producing
4%

Output

0.27 MW

Today

12.2 MWh

Wind

5.7 m/s

Tracker block

PV-01

Array Technologies DuraTrack HZ v3 · 4.0 MWp

Producing
44%

Output

1.78 MW

Today

5.6 MWh

Availability

94.4 %

Tracker block

PV-02

Array Technologies DuraTrack HZ v3 · 4.0 MWp

Producing
25%

Output

1.00 MW

Today

4.4 MWh

Availability

97.3 %

Tracker block

PV-03

Array Technologies DuraTrack HZ v3 · 2.4 MWp

Producing
32%

Output

0.76 MW

Today

3.2 MWh

Availability

96.6 %

Tracker block

PV-04

Array Technologies DuraTrack HZ v3 · 2.4 MWp

Producing
37%

Output

0.89 MW

Today

3.5 MWh

Availability

99.0 %

Tracker block

PV-05

Soltec SF7 · 3.2 MWp

Producing
37%

Output

1.17 MW

Today

4.0 MWh

Availability

94.9 %

Tracker block

PV-06

Soltec SF7 · 3.2 MWp

Producing
30%

Output

0.95 MW

Today

3.9 MWh

Availability

97.3 %

Tracker block

PV-07

Nextracker NX Horizon · 3.2 MWp

Producing
31%

Output

1.00 MW

Today

4.3 MWh

Availability

93.9 %

Tracker block

PV-08

Nextracker NX Horizon · 2.4 MWp

Producing
41%

Output

0.98 MW

Today

2.8 MWh

Availability

97.4 %

Tracker block

PV-09

Array Technologies DuraTrack HZ v3 · 3.2 MWp

Producing
45%

Output

1.44 MW

Today

4.2 MWh

Availability

94.7 %

Tracker block

PV-10

Nextracker NX Horizon · 2.4 MWp

Standby
0%

Output

0.00 MW

Today

3.2 MWh

Availability

98.5 %

Inverter skid

INV-01

SMA Sunny Central 4600 UP · 3.1 MVA

Producing
30%

Output

0.93 MW

Today

6.5 MWh

Availability

97.2 %

Inverter skid

INV-02

Huawei SUN2000-215KTL · 4.6 MVA

Standby
0%

Output

0.00 MW

Today

8.4 MWh

Availability

97.0 %

Inverter skid

INV-03

Sungrow SG3125HV-MV · 3.1 MVA

Producing
25%

Output

0.79 MW

Today

9.5 MWh

Availability

96.6 %

Inverter skid

INV-04

Sungrow SG3125HV-MV · 5.0 MVA

Producing
34%

Output

1.70 MW

Today

10.9 MWh

Availability

95.4 %

Inverter skid

INV-05

Huawei SUN2000-215KTL · 4.6 MVA

Producing
53%

Output

2.43 MW

Today

12.9 MWh

Availability

98.3 %

Inverter skid

INV-06

Huawei SUN2000-215KTL · 3.1 MVA

Maintenance
0%

Output

0.00 MW

Today

4.9 MWh

Availability

98.5 %

Battery container

BESS-01

Tesla Megapack 2XL · 5.0 MW

Producing
64%

Output

3.20 MW

Today

0.0 MWh

State of charge

68 %

Battery container

BESS-02

CATL EnerOne+ · 3.9 MW

Producing
67%

Output

2.61 MW

Today

0.0 MWh

State of charge

68 %

Alarms
Site alarms
Most recent events from this site's assets.

Service interval exceeded

WTG-05· 11-16 08:34
Medium

Soiling loss above threshold

PV-05· 11-16 08:02
Medium

Blade ice detected

WTG-07· 11-16 05:05
High

Soiling loss above threshold

PV-08· 11-16 03:25
Low

IGBT temperature high

INV-06· 11-15 19:40
Medium

Row stowed – high wind

PV-06· 11-15 17:29
Medium