DMU-03

DMG MORI DMU 50 (3rd Generation) · Siemens SINUMERIK ONE · Bay 1 · Cell C · s/n DMU50-22211

Live machine view
Five-axis cycle
X/Y/Z, the swivelling B trunnion and the C rotary table follow live telemetry; the door opens when the machine stops. Drag to rotate, scroll to zoom.
Cutting
Effectiveness
OEE this shift
Early (06:00–14:00) · 370 of 423 min running
64%

Availability

87.3%

Performance

74.7%

Quality

98.6%

Current job
WO-24117
Valve block · BH-9021-D

Pieces

7 / 20

Cycle time

6m 35s

This piece

4s elapsed

Operator

Sandro Pereira

Tool

T7 · Ø6 finishing end mill

Tool life left

8%

Finishes

16 Nov 14:09

Losses
Downtime by reason
53.6 minutes lost this shift, biggest first.

Setup / first-off

20.3 min

Tool change

12.6 min

Breakdown

6.2 min

Waiting QA

5.8 min

No material

5.3 min

No operator

3.2 min

Quality
Pieces this shift
Ideal 228 s versus actual 305 s per piece.

Good

71

Scrap

1

Rework

0

OEE per hour · %

Queue
Jobs on this machine (3)
The job on the spindle and everything queued behind it, earliest due date first.

WO-24117

Brunner Hydraulik · BH-9021-D OP30 · Al 6082 · setup 46 min

Late

7/20 · due 16 Nov 00:03

WO-24121

Sandvik Tooling · ST-3390-A OP20 · H13 tool steel · setup 35 min

Queued

0/20 · due 18 Nov 00:03

WO-24125

Hot

Helvetica Medtech · HM-2208-C OP10 · 316L stainless · setup 86 min

Queued

0/12 · due 19 Nov 00:03

Readings
Live telemetry
Polled every 5 seconds · spindle 14,433 h, service in 165 h

Spindle load

60 %

Spindle speed

8,415 rpm

Feed rate

1,467 mm/min

Spindle temp

47.1 °C

Coolant temp

25.9 °C

Coolant pressure

18.5 bar

Vibration

1.9 mm/s

Axis load B

31 %

Axis positions

X

155.2

Y

-36.1

Z

-172.4

B

-26.7

C

289.6

Spindle history
Spindle load, speed and vibration

Spindle load · %

Spindle speed · rpm

Vibration · mm/s

Alarms
Alarms (8)

Door interlock opened during cycle

Alarm 6621 · 11-16 11:52

High

B axis drive temperature high

Alarm 1105 · 11-16 11:02

Medium

Tool life expired on T7, change required

Alarm 2019 · 11-16 10:40

Low

Tool life expired on T7, change required

Alarm 2019 · 11-15 11:06

High

C axis following error

Alarm 1188 · 11-15 02:11

Medium

Coolant level low in the tank

Alarm 7014 · 11-14 21:31

High

Coolant level low in the tank

Alarm 7014 · 11-14 20:44

High

Coolant level low in the tank

Alarm 7014 · 11-14 16:48

High