DMU-03

DMG MORI DMU 50 (3rd Generation) · Siemens SINUMERIK ONE · Bay 1 · Cell C · s/n DMU50-22211

Live machine view
Five-axis cycle
X/Y/Z, the swivelling B trunnion and the C rotary table follow live telemetry; the door opens when the machine stops. Drag to rotate, scroll to zoom.
Cutting
Effectiveness
OEE this shift
Early (06:00–14:00) · 390 of 435 min running
66%

Availability

89.5%

Performance

74.7%

Quality

98.7%

Current job
WO-24117
Valve block · BH-9021-D

Pieces

7 / 20

Cycle time

6m 35s

This piece

5m 35s elapsed

Operator

Sandro Pereira

Tool

T9 · Ø12 face mill

Tool life left

7%

Finishes

16 Nov 14:21

Losses
Downtime by reason
45.6 minutes lost this shift, biggest first.

Setup / first-off

17.9 min

Tool change

7.7 min

No material

6.6 min

Breakdown

5.5 min

Waiting QA

5.2 min

No operator

2.8 min

Quality
Pieces this shift
Ideal 228 s versus actual 305 s per piece.

Good

75

Scrap

1

Rework

0

OEE per hour · %

Queue
Jobs on this machine (3)
The job on the spindle and everything queued behind it, earliest due date first.

WO-24117

Brunner Hydraulik · BH-9021-D OP30 · Al 6082 · setup 46 min

Late

7/20 · due 16 Nov 00:15

WO-24121

Sandvik Tooling · ST-3390-A OP20 · H13 tool steel · setup 35 min

Queued

0/20 · due 18 Nov 00:15

WO-24125

Hot

Helvetica Medtech · HM-2208-C OP10 · 316L stainless · setup 86 min

Queued

0/12 · due 19 Nov 00:15

Readings
Live telemetry
Polled every 5 seconds · spindle 14,433 h, service in 165 h

Spindle load

59 %

Spindle speed

8,415 rpm

Feed rate

1,725 mm/min

Spindle temp

47.3 °C

Coolant temp

26.7 °C

Coolant pressure

16.9 bar

Vibration

1.81 mm/s

Axis load B

22 %

Axis positions

X

-152.5

Y

40.0

Z

-66.8

B

-42.6

C

74.0

Spindle history
Spindle load, speed and vibration

Spindle load · %

Spindle speed · rpm

Vibration · mm/s

Alarms
Alarms (8)

Door interlock opened during cycle

Alarm 6621 · 11-16 12:02

High

B axis drive temperature high

Alarm 1105 · 11-16 11:11

Medium

Tool life expired on T7, change required

Alarm 2019 · 11-16 10:50

Low

Tool life expired on T7, change required

Alarm 2019 · 11-15 11:15

High

C axis following error

Alarm 1188 · 11-15 02:20

Medium

Coolant level low in the tank

Alarm 7014 · 11-14 21:40

High

Coolant level low in the tank

Alarm 7014 · 11-14 20:53

High

Coolant level low in the tank

Alarm 7014 · 11-14 16:58

High